End-tidal CO2 monitoring in cardiac arrest
Pitfall: a common pitfall is to stop chest compressions as soon the end-tidal CO2 jumps to 40. CPR should only be discontinued after persistent end-tidal CO2 >40 and additional signs of ROSC are present. |
![]() Author
|